R410A D Type Indoor Unit Lineup
◎:Tailored to specifications ordered.
| Indoor Unit Type | Model | Shape | P22 | P28 | P36 | P45 | P56 | P71 | P80 | P90 | P112 | P140 | P160 | P224 | P280 | P335 | P450 | P560 | P800 | P1120 | P1400 | P1600 | |||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Cooling capacity(kW) |
2.2 | 2.8 | 3.6 | 4.5 | 5.6 | 7.1 | 8.0 | 9.0 | 11.2 | 14.0 | 16.0 | 22.4 | 28.0 | 35.5 | 45.0 | 56.0 | 80.0 | 112.0 | 140.0 | 160.0 | |||||||||
| Heating capacity(kW) |
2.5 | 3.2 | 4.0 | 5.0 | 6.3 | 8.0 | 9.0 | 10.0 | 12.5 | 16.0 | 18.0 | 25.0 | 31.5 | 40.0 | 50.0 | 63.0 | 90.0 | 125.0 | 160.0 | 180.0 | |||||||||
| Standard Type | |||||||||||||||||||||||||||||
| Ceiling (Built-in Cassette) |
Round floor type Facing panel |
YZCP28~160MB PCP160KF |
![]() |
● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |||||||||||||||
| Double flow type Facing panel |
YZWP22~160M PWJ~LF |
![]() |
● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |||||||||||||||
| Single flow type Facing panel |
YZK22~36M PEJ36KF |
![]() |
● | ● | ● | ||||||||||||||||||||||||
| Corner type Facing panel |
YZBP28~71M PKJ~LF |
![]() |
● | ● | ● | ● | ● | ||||||||||||||||||||||
| Ceiling(built-in) Facing panel |
YZDP45~280M(A) | ![]() |
● | ● | ● | ● | ● | ● | ● | ● | ● | ||||||||||||||||||
| Ceiling(built-in duct) | YZSDP22~71M | ![]() |
● | ● | ● | ● | ● | ● | ◎ | ◎ | |||||||||||||||||||
| Thin(duct) | YZSDP22~71M | ![]() |
● | ● | ● | ● | ● | ● | |||||||||||||||||||||
| Ceiling(hanging) | YZHP36~160M | ● | ● | ● | ● | ● | ● | ● | ● | ● | |||||||||||||||||||
| Wall(hanging) | YZAP28~71M | ![]() |
● | ● | ● | ● | ● | ||||||||||||||||||||||
| Floor(low) | YZFP28~71M | ● | ● | ● | ● | ● | |||||||||||||||||||||||
| Floor(low, built-in) | YZMP28~71M | ◎ | ◎ | ◎ | ◎ | ◎ | |||||||||||||||||||||||
| Floor(duct) | YZFVP140~1600M | ![]() |
◎ | ◎ | ◎ | ◎ | ◎ | ◎ | ◎ | ◎ | ◎ | ◎ | |||||||||||||||||
| Wall(built-in) | YZBWP140~280M | ![]() |
◎ | ◎ | ◎ | ||||||||||||||||||||||||
| Hospital clean air conditioner(integrated blow outlet) | YZBCP45~71M | ![]() |
◎ | ◎ | ◎ | ||||||||||||||||||||||||
| Hospital clean air conditioner(separated blow outlet) | YZBCP71MP | ![]() |
◎ | ||||||||||||||||||||||||||
| Ceiling(hanging, kitchen use) | YZHTP80・140M | ◎ | ◎ | ||||||||||||||||||||||||||
| Ceiling(hanging, plant use) | YZHFP140・280M | ◎ | ◎ | ||||||||||||||||||||||||||
| Outside Air Treatment Air Conditioner | |||||||||||||||||||||||||||||
| Ceiling(built-in duct) | YZDP140~280MF | ![]() |
◎ | ◎ | ◎ | ||||||||||||||||||||||||
| Wall(built-in) | YZBWP140~280MF | ![]() |
◎ | ◎ | ◎ | ||||||||||||||||||||||||
| Outside Air Treatment Unit | |||||||||||||||||||||||||||||
| Ceiling(built-in duct) | VKMP50~100GAM | ![]() |
◎ | ◎ | ◎ | ||||||||||||||||||||||||
- *1 When connecting duct type indoor units placed on the floor, the capacity of the indoor unit should not exceed that of the outdoor unit.
- *2 The outside air treatment air conditioner handles only the outside air load. Install the building multiple units, etc. separately for indoor load (indoor air conditioning). The outside air treatment air conditioner cannot be integrated with the refrigerant system of the indoor air conditioners or the remote control system of the group units.
- *3 The outside air treatment unit can be operated either separately or in coordination with the indoor units.
- *4 When the total capacity of indoor units exceeds that of the outdoor unit, the capacity of the indoor units may drop to a certain extent when all are operated.
- *5 YZFVP1120M is combined with two P560 indoor units.
- *6 YZFVP1600M is combined with three P560 indoor units.
- *7 It is not possible to connect the floor, duct type (355~1600), outside air treatment air conditioner or outside air treatment unit to the cooling & heating air conditioner. It is not possible to implement (high power) multiple-connection of the floor, duct type (1120, 1600) and the outside air treatment air conditioner with the high power unit.
- *8 When the (high power) multiple connection of the floor, duct type with the cooling and heating unit is implemented, it is not possible to use the spot energy-saving mode or the outside air treatment mode.