Indoor Unit

R410A D Type Indoor Unit Lineup

◎:Tailored to specifications ordered.

Indoor Unit Type Model Shape P22 P28 P36 P45 P56 P71 P80 P90 P112 P140 P160 P224 P280 P335 P450 P560 P800 P1120 P1400 P1600
Cooling
capacity(kW)
2.2 2.8 3.6 4.5 5.6 7.1 8.0 9.0 11.2 14.0 16.0 22.4 28.0 35.5 45.0 56.0 80.0 112.0 140.0 160.0
Heating
capacity(kW)
2.5 3.2 4.0 5.0 6.3 8.0 9.0 10.0 12.5 16.0 18.0 25.0 31.5 40.0 50.0 63.0 90.0 125.0 160.0 180.0
Standard Type
Ceiling
(Built-in Cassette)
Round floor type
Facing panel
YZCP28~160MB
PCP160KF
                 
Double flow type
Facing panel
YZWP22~160M
PWJ~LF
               
Single flow type
Facing panel
YZK22~36M
PEJ36KF
                                 
Corner type
Facing panel
YZBP28~71M
PKJ~LF
                             
Ceiling(built-in)
Facing panel
YZDP45~280M(A)                      
Ceiling(built-in duct) YZSDP22~71M                        
Thin(duct) YZSDP22~71M                            
Ceiling(hanging) YZHP36~160M                      
Wall(hanging) YZAP28~71M                              
Floor(low) YZFP28~71M                              
Floor(low, built-in) YZMP28~71M                              
Floor(duct) YZFVP140~1600M                    
Wall(built-in) YZBWP140~280M                                  
Hospital clean air conditioner(integrated blow outlet) YZBCP45~71M                                  
Hospital clean air conditioner(separated blow outlet) YZBCP71MP                                      
Ceiling(hanging, kitchen use) YZHTP80・140M                                    
Ceiling(hanging, plant use) YZHFP140・280M                                    
Outside Air Treatment Air Conditioner
Ceiling(built-in duct) YZDP140~280MF                                  
Wall(built-in) YZBWP140~280MF                                  
Outside Air Treatment Unit
Ceiling(built-in duct) VKMP50~100GAM                                  
  • *1 When connecting duct type indoor units placed on the floor, the capacity of the indoor unit should not exceed that of the outdoor unit.
  • *2 The outside air treatment air conditioner handles only the outside air load. Install the building multiple units, etc. separately for indoor load (indoor air conditioning). The outside air treatment air conditioner cannot be integrated with the refrigerant system of the indoor air conditioners or the remote control system of the group units.
  • *3 The outside air treatment unit can be operated either separately or in coordination with the indoor units.
  • *4 When the total capacity of indoor units exceeds that of the outdoor unit, the capacity of the indoor units may drop to a certain extent when all are operated.
  • *5 YZFVP1120M is combined with two P560 indoor units.
  • *6 YZFVP1600M is combined with three P560 indoor units.
  • *7 It is not possible to connect the floor, duct type (355~1600), outside air treatment air conditioner or outside air treatment unit to the cooling & heating air conditioner. It is not possible to implement (high power) multiple-connection of the floor, duct type (1120, 1600) and the outside air treatment air conditioner with the high power unit.
  • *8 When the (high power) multiple connection of the floor, duct type with the cooling and heating unit is implemented, it is not possible to use the spot energy-saving mode or the outside air treatment mode.